Adıyaman Üniversitesi Kurumsal Arşivi

Correlation of Non-invasive Tear Break-Up Time with Tear Osmolarity and Other Invasive Tear Function Tests

Basit öğe kaydını göster

dc.contributor.author Özülken, Kemal
dc.contributor.author Aksoy Aydemir, Gözde
dc.contributor.author Tekin, Kemal
dc.contributor.author Mumcuoğlu, Tarkan
dc.date.accessioned 2025-09-29T10:57:20Z
dc.date.available 2025-09-29T10:57:20Z
dc.date.issued 2020
dc.identifier.issn 0882-0538
dc.identifier.uri http://dspace.adiyaman.edu.tr:8080/xmlui/handle/20.500.12414/6757
dc.description.abstract Aim: To compare the outcomes of non-invasive break-up time (NI-BUT) test and the other conventional dry eye tests. Methods: The right eyes of 170 subjects were included in the study. In order to evaluate the tear quality of the patients, NI-BUT levels were measured by the Scheimplug-Placido disk system (Sirius topography). Tear osmolarity test was performed with TearLab Osmolarity System. Topical anesthesia-assisted type I Schirmer test and topical anesthesia-assisted BUT were lastly applied to all patients in order not to affect other measurements. Results: The mean NI-BUT value was 9.59 +/- 4.37 sec, tear osmolarity was 292.93 +/- 9.30 mOsm/L, Schirmer test was 15.32 +/- 6.05 mm/5 min, and biomicroscopic BUT value was 8.98 +/- 3.79 sec. The Schirmer test results were statistically significantly correlated with biomicroscopic BUT and NI-BUT values (p = .019, r = 0.180 and p = .030, r = 0.166; respectively). It was also found that tear osmolarity was strongly and inversely correlated with biomicroscopic BUT and topographic NI-BUT values (p < .001, r = -0.554 and p < .001, r = -0.528; respectively). There was no significant correlation between Schirmer test and tear osmolarity. Conclusion: It is important to use a sensitive, reproducible and non-invasive method in the evaluation of tear functions. We think that the objective and noninvasive topographic NI-BUT measurements and the minimally invasive osmolarity measurements should be used more frequently in practice because they are correlated with the measurements obtained by invasive methods and should be widespread in clinics. tr
dc.language.iso en tr
dc.publisher TAYLOR & FRANCIS INC tr
dc.subject Dry eye tr
dc.subject break-up time tr
dc.subject non-invasive break-up time tr
dc.subject osmolarity test tr
dc.subject Schirmer test tr
dc.title Correlation of Non-invasive Tear Break-Up Time with Tear Osmolarity and Other Invasive Tear Function Tests tr
dc.type Article tr
dc.contributor.authorID 0000-0003-2604-2981 tr
dc.contributor.authorID 0000-0002-7461-6129 tr
dc.contributor.department TOBB ETU Med Sch, Ophthalmol Dept tr
dc.contributor.department Adiyaman Univ Training & Res Hosp, Dept Ophthalmol,1 tr
dc.contributor.department Van Ercis State Hosp, Ophthalmol Dep tr
dc.identifier.endpage 85 tr
dc.identifier.issue 1 tr
dc.identifier.startpage 78 tr
dc.identifier.volume 35 tr
dc.source.title SEMINARS IN OPHTHALMOLOGY tr


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster