Adıyaman Üniversitesi Kurumsal Arşivi

Comparison of Two Different Accelerated Corneal Cross-linking Procedure Outcomes in Patients with Keratoconus

Basit öğe kaydını göster

dc.contributor.author Özülken, Kemal
dc.contributor.author Asoy Aydemir, Gözde
dc.contributor.author Kızıltoprak, Hasan
dc.contributor.author Yüksel, Erdem
dc.date.accessioned 2025-09-01T06:05:24Z
dc.date.available 2025-09-01T06:05:24Z
dc.date.issued 2020
dc.identifier.issn 2146-3123
dc.identifier.uri http://dspace.adiyaman.edu.tr:8080/xmlui/handle/20.500.12414/6717
dc.description.abstract Background: Corneal cross-linking treatment is the unique treatment method that can cease the progression of keratoconus disease. Because of the long duration of conventional treatment, accelerated cross-linking treatment methods are being developed. Aims: To compare two different accelerated corneal cross-linking protocols in terms of postoperative visual acuity and topographic findings (higher-order aberrations and keratometry values). Study Design: Retrospective comparative study. Methods: Sixty-live eyes of 43 patients (30 men and 13 women) who underwent two different accelerated corneal cross-linking protocols (10 min, 9 mW/cm(2) and 5 min, 18 mW/cm(2)) for progressive keratoconus were retrospectively analyzed. Patients were divided into two groups according to the accelerated corneal cross-linking treatment protocol: group 1 (10 min, 9 mW/cm(2), 32 eyes of 21 patients) and group 2 (5 min, 18 mW/cm(2), 33 eyes of 22 patients). Uncorrected visual acuity and best-corrected visual acuity values and topographic findings (central corneal thickness and flat and steep keratometry values) were recorded preoperatively and 6 months after corneal cross-linking treatment. High-order aberration values measured with Pentacam preoperatively and 6 months after corneal cross-linking were also recorded. Results: In both groups, a significant improvement was detected in the uncorrected visual acuity and best-corrected visual acuity levels preoperatively and 6 months postoperatively (group 1: p=0.001, p=0.001 and group 2: p=0.001. p=0.001. respectively). In addition, central corneal thickness values decreased significantly in both groups (p=0.006 and 0.001). Trefoil values showed no significant difference preoperatively and 6 months postoperatively in group 1 (p=0.160 and 0.620, respectively). In groups 1 and 2, coma values were found to decrease significantly in the oth postoperative month compared with preoperative values (p=0.001 and 0.020, respectively). There was no significant difference between preoperative and 6th month postoperative horizontal and vertical trefoil values in both groups (p=0.850 and 0.140, respectively). There was no significant difference between the two groups in terms of preoperative and 6th month postoperative higher-order aberrations, refractive errors, keratometry values, and uncorrected visual acuity and best-corrected visual acuity levels. Conclusion: Both accelerated conical cross-linking procedures provide similar improvement in topographic findings, coma values and visual acuity. tr
dc.language.iso en tr
dc.publisher GALENOS PUBL HOUSE tr
dc.subject Accelarated cross-linking tr
dc.subject comacorneal cross-linkin tr
dc.subject cx1 tr
dc.subject higher-order aberations tr
dc.subject keratoconus tr
dc.title Comparison of Two Different Accelerated Corneal Cross-linking Procedure Outcomes in Patients with Keratoconus tr
dc.type Article tr
dc.contributor.authorID 0000-0003-2604-2981 tr
dc.contributor.authorID 0000-0002-5708-9283 tr
dc.contributor.authorID 0000-0001-7100-9107 tr
dc.contributor.department TOBB ETU Sch Med, Dept Ophthalmol tr
dc.contributor.department Adiyaman Univ Training & Res Hosp, Clin Ophthalmol, tr
dc.contributor.department Bingol Matern & Child Dis Hosp, Clin Ophthalmol tr
dc.contributor.department Kastamonu Univ, Dept Ophthalmol, Sch Med, tr
dc.identifier.endpage 137 tr
dc.identifier.issue 3 tr
dc.identifier.startpage 131 tr
dc.identifier.volume 37 tr
dc.source.title BALKAN MEDICAL JOURNAL tr


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster