Adiyaman University Repository

The utility of ADC measurement techniques for differentiation of low- and high-grade clear cell RCC

Show simple item record

dc.contributor.author Aslan, Ahmet
dc.contributor.author İnan, İbrahim
dc.contributor.author Aktan, Ahmet
dc.contributor.author ve öte.
dc.date.accessioned 2024-06-06T05:51:22Z
dc.date.available 2024-06-06T05:51:22Z
dc.date.issued 2018
dc.identifier.issn 0137-7183
dc.identifier.uri http://dspace.adiyaman.edu.tr:8080/xmlui/handle/20.500.12414/5210
dc.description.abstract Purpose: To evaluate the diffusion properties of clear cell renal cell carcinoma (ccRCC) on magnetic resonance imaging (MRI) concerning their Fuhrman nuclear grades and sizes, and to compare the diagnostic performance of two ROI placement techniques for apparent diffusion coefficient (ADC) measurement (entire mass vs. only the darkest region of the mass). Material and methods: Fifty-one ccRCC were enrolled in the study and grouped into low-grade ccRCC (Fuhrman grade 1 and 2, n = 37) and high-grade ccRCC (Fuhrman grade 3 and 4, n = 14). Selective ADC (Sel-ADC) measurement was performed by placing a circular ROI that included the darkest region of the tumour on ADC map images. Extensive ADC (Ext-ADC) measurement was performed by drawing an ROI that covered the entire tumour. Results: The Sel-ADC value was lower in high-grade ccRCC (p = 0.019), whereas the Ext-ADC value did not show a statistically significant difference (p = 0.42). Sel-ADC value of a <= 1.405 mm(2)/s has a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy value of 78.6, 72.2, 73.87, 77.13, and 75.4, respectively, to differentiate high-grade from low-grade ccRCC. The size and Fuhrman grade of the ccRCC were inversely correlated with the Sel-ADC value; however, the correlations were weak (r = -0.322, p = 0.021 and r = -0.376, p = 0.006, respectively). There was no difference between ADC values of small (<= 4 cm) and large (> 4 cm) ccRCCs. Conclusions: The ADC value of the darkest region in solid part of the ccRCC may play a role in predicting the nuclear grade of ccRCC. tr
dc.language.iso en tr
dc.publisher INT SCIENTIFIC INFORMATION INC tr
dc.subject APPARENT DIFFUSION-COEFFICIENT tr
dc.subject TUMOR SIZE tr
dc.subject CARCINOMA tr
dc.title The utility of ADC measurement techniques for differentiation of low- and high-grade clear cell RCC tr
dc.type Article tr
dc.contributor.authorID 0000-0003-1433-6149 tr
dc.contributor.department Istanbul Medeniyet Univ, Goztepe Training & Res Hosp, Dept Radiol, tr
dc.contributor.department Adiyaman Univ, Training & Res Hosp, Dept Radiol, tr
dc.identifier.endpage E451 tr
dc.identifier.startpage E446 tr
dc.identifier.volume 83 tr
dc.source.title POLISH JOURNAL OF RADIOLOGY tr


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account