Adıyaman Üniversitesi Kurumsal Arşivi

Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter

Basit öğe kaydını göster

dc.contributor.author Khachatryan, V.
dc.contributor.author Sirunyan, A. M.
dc.contributor.author Tumasyan, A.
dc.date.accessioned 2023-10-02T05:18:27Z
dc.date.available 2023-10-02T05:18:27Z
dc.date.issued 2016
dc.identifier.issn 1748-0221
dc.identifier.uri http://dspace.adiyaman.edu.tr:8080/xmlui/handle/20.500.12414/4545
dc.description.abstract We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects. tr
dc.language.iso en tr
dc.publisher IOP Publishing Ltd tr
dc.subject Radiation damage to detector materials (solid state) tr
dc.subject Radiation-hard detectors tr
dc.subject Scintillators and scintillating fibres and light guides tr
dc.subject Calorimeters tr
dc.title Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter tr
dc.type Article tr
dc.contributor.department Yerevan Phys Inst tr
dc.identifier.volume 11 tr
dc.source.title JOURNAL OF INSTRUMENTATION tr


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster