Adiyaman University Repository

Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer

Show simple item record

dc.contributor.author Altıparmak, Zeynep
dc.contributor.author Yağcı, Ramazan
dc.contributor.author Güler, Emre
dc.contributor.author ve diğerleri...
dc.date.accessioned 2022-12-30T08:29:49Z
dc.date.available 2022-12-30T08:29:49Z
dc.date.issued 2015
dc.identifier.issn 1300-0659
dc.identifier.uri http://dspace.adiyaman.edu.tr:8080/xmlui/handle/20.500.12414/4162
dc.description.abstract Objectives: To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. Materials and Methods: Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal higher-order wavefront aberrations (6.0 mm pupil), pachymetry at the central, paracentral, and peripheral zones, and anterior chamber depth (ACD). Repeatability was assessed by calculating the within subject standard deviation, precision, repeatability, and intraclass correlation coefficient (ICC). Bland-Altman analysis was used for assessing reproducibility. Results: Thirty eyes of 30 patients were included. The best ICC values were for corneal pachymetry and ACD. For both observers, acceptable ICC was also achieved for the other parameters, the only exceptions being posterior corneal astigmatism and total high order aberration. The 95% LoA (Limits of Agreement) values for all measurements showed small variability between the two examiners. Conclusion: The Galilei system provided reliable measurements of anterior segment parameters. Therefore, the instrument can be confidently used for routine clinical use and research purposes. tr
dc.language.iso en tr
dc.publisher Turkish Ophthalmological Soc tr
dc.subject Galilei tr
dc.subject Intraobserver tr
dc.subject Interobserver repeatability tr
dc.subject Wavefront aberrations tr
dc.title Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer tr
dc.type Article tr
dc.contributor.department Ulucanlar Eye Training & Res Hosp, Ankara, Turkey tr
dc.contributor.department Ercis State Hosp, Clin Ophthalmol, Van, Turkey tr
dc.contributor.department Pamukkale Univ Fac Med, Dept Ophthalmol, Denizli, Turkey tr
dc.identifier.endpage 248 tr
dc.identifier.issue 6 tr
dc.identifier.startpage 243 tr
dc.identifier.volume 45 tr
dc.source.title Türk Oftalmoloji Dergisi-Turkish Journal Of Ophthalmology tr


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account