| dc.description.abstract | The current study simultaneously examined the treatability of wastewater by electrodialysis unit and recovery of ions removed as acidic/alkaline solutions. With a bipolar membrane electrodialysis process, the removed ions are stored separately in anolyte/catholyte solutions, and then turned into mixed acids and bases. After the treatment of the leachate using the BMED process, the molar concentration of H+ ions in the acidic solution and the OH- ions in the alkaline solution reached up to 0.095 and 0.048M (conditions: 1L wastewater and 1L anolyte/catholyte solutions), respectively. When the ratio of wastewater to initial volume of anolyte and catholyte was 1/4 (1L wastewater and 0.25L anolyte or catholyte solutions) at the end of a 360-min treatment period, 3.8- (from 0.01995 to 0.07586M for [H+]) and 3.98- (from 0.02344 to 0.09333M for [OH-]) times more intense acid and base concentrations were determined, respectively. This demonstrates that the process can be considered as a cleaner technology for the treatability of wastewater by obtaining more concentrated acid and base as recovered material and fewer byproducts. | tr | 
| dc.language.iso | en | tr | 
| dc.publisher | Desalınatıon Publ | tr | 
| dc.subject | Electrodialysis | tr | 
| dc.subject | Bipolar membrane | tr | 
| dc.subject | Leachate | tr | 
| dc.subject | Desalination | tr | 
| dc.subject | Recovery | tr | 
| dc.title | Recovery of mixed acid and base from wastewater with bipolar membrane electrodialysis-a case study | tr | 
| dc.type | Article | tr | 
| dc.contributor.authorID | 0000-0003-3037-2713 | tr | 
| dc.contributor.authorID | 0000-0002-1012-0298 | tr | 
| dc.contributor.authorID | 0000-0002-4189-5512 | tr | 
| dc.contributor.authorID | 0000-0001-7951-8125 | tr | 
| dc.contributor.department | Yildiz Tech Univ, Dept Environm Engn, Fac Civil Engn, | tr | 
| dc.contributor.department | Adiyaman Univ, Dept Environm Engn, Fac Engn, | tr | 
| dc.identifier.endpage | 5173 | tr | 
| dc.identifier.issue | 11 | tr | 
| dc.identifier.startpage | 5165 | tr | 
| dc.identifier.volume | 57 | tr | 
| dc.source.title | Desalınatıon And Water Treatment | tr |