Adiyaman University Repository

Olecranon anatomy: Use of a novel proximal interlocking screw for intramedullary nailing, a cadaver study

Show simple item record

dc.contributor.author Küçükdurmaz, Fatih
dc.contributor.author Sağlam, Necdet
dc.contributor.author Kgir, İsmail
dc.contributor.author Şen, Cengiz
dc.contributor.author Akpınar, Fuat
dc.date.accessioned 2022-10-14T05:57:49Z
dc.date.available 2022-10-14T05:57:49Z
dc.date.issued 2013
dc.identifier.issn 2218-5836
dc.identifier.uri http://dspace.adiyaman.edu.tr:8080/xmlui/handle/20.500.12414/3693
dc.description.abstract AIM: To define the optimum safe angle of use for an eccentrically aligned proximal interlocking screw (PIS) for intramedullary nailing (IMN). METHODS: Thirty-six dry cadaver ulnas were split into two equal pieces sagitally. The following points were identified for each ulna: the deepest point of the incisura olecrani (A), the point where perpendicular lines from A and the ideal IMN entry point (D) are intersected (C) and a point at 3.5 mm (2 mm safety distance from articular surface + 1.5 mm radius of PIS) posterior from point A (B). We calculated the angle of screws inserted from point D through to point B in relation to D-C and B-C. In addition, an eccentrically aligned screw was inserted at a standard 20 degrees through the anterior cortex of the ulna in each bone and the articular surface was observed macroscopically for any damage. RESULTS: The mean A-C distance was 9.6 mm (mean +/- SD, 9.600 +/- 0.763 mm), A-B distance was 3.5 mm, C-D distance was 12.500 mm (12.500 +/- 1.371 mm) and the mean angle was 25.9 degrees (25.9 degrees +/- 2.0 degrees). Lack of articular damage was confirmed macroscopically in all bones after the 20.0 degrees eccentrically aligned screws were inserted. Intramedullary nail fixation systems have well known biological and biomechanical advantages for osteosynthesis. However, as well as these well-known advantages, IMN fixation of the ulna has some limitations. Some important limitations are related to the proximal interlocking of the ulna nail. The location of the PIS itself limits the indications for which intramedullary systems can be selected as an implant for the ulna. The new PIS design, where the PIS is aligned 20 degrees eccentrically to the nail body, allows fixing of fractures even at the level of the olecranon without disturbing the joint. It also allows the eccentrically aligned screw to be inserted in any direction except through the proximal radio-ulnar joint. Taking into consideration our results, we now use a 20 degrees eccentrically aligned PIS for all ulnas. In our results, the angle required to insert the PIS was less than 20 degrees for only one bone. However, 0.7 degrees difference corresponds to placement of the screw only 0.2 mm closer to the articular surface. As we assume 2.0 mm to be a safe distance, a placement of the screw 0.2 mm closer to the articular surface may not produce any clinical symptoms. CONCLUSION: The new PIS may give us the opportunity to interlock IMN without articular damage and confirmation by fluoroscopy if the nail is manufactured with a PIS aligned at a 20.0 degrees fixed angle in relation to the IMN. (C) 2013 Baishideng. All rights reserved. tr
dc.language.iso en tr
dc.publisher Baıshıdeng Publıshıng Group Inc tr
dc.subject Interlocking screw tr
dc.subject Intramedullary nailing tr
dc.subject Ulna fracture tr
dc.subject Ulna anatomy tr
dc.title Olecranon anatomy: Use of a novel proximal interlocking screw for intramedullary nailing, a cadaver study tr
dc.type Article tr
dc.contributor.authorID 0000-0002-5557-8542 tr
dc.contributor.authorID 0000-0001-9788-580X tr
dc.contributor.department Bezmialem Vakif Univ, Dept Orthoped & Traumatol tr
dc.contributor.department Umraniye Res & Educ Hosp, Dept Orthoped & Traumatol, tr
dc.contributor.department Adiyaman Univ, Dept Orthopaed & Traumatol, Sch Med, tr
dc.contributor.department Abant Izzet Baysal Univ, Dept Orthoped & Traumatol, tr
dc.identifier.endpage 133 tr
dc.identifier.issue 3 tr
dc.identifier.startpage 130 tr
dc.identifier.volume 4 tr
dc.source.title World Journal Of Orthopedıcs tr


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account