Adiyaman University Repository

Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery

Show simple item record

dc.contributor.author Şimşek, Ali
dc.contributor.author Çiftçi, Süleyman
dc.date.accessioned 2022-05-17T08:02:01Z
dc.date.available 2022-05-17T08:02:01Z
dc.date.issued 2012
dc.identifier.issn 1177-5483
dc.identifier.uri http://dspace.adiyaman.edu.tr:8080/xmlui/handle/20.500.12414/2978
dc.description.abstract Background: The aim of this study was to assess the value of ultrasonic biomicroscopy in reporting decreases in intraocular pressure resulting from changes in anterior chamber depth and angle after phacoemulsification and intracapsular lens implantation in patients with cataract. Methods: This prospective interventional case series included 50 eyes of 50 consecutive subjects operated at the same center. Patients with eye disease affecting visual acuity, a history of eye surgery, corneal surface irregularities, a pupil diameter < 5 mm after preoperative dilation, aged younger than 35 years, posterior capsule perforation, iris dialysis during surgery, intensive postoperative corneal edema, and inability to attend adequate follow-up were excluded. Intraocular pressure, anterior chamber depth and angle, and corneal thickness were measured before and one month after surgery. Results: The mean preoperative intraocular pressure was 14 mmHg and postoperatively was 11 mmHg. Mean anterior chamber depth preoperatively was 2.8 mm and increased to 3.7 mm postoperatively. The mean anterior chamber angle was measured as 27 degrees preoperatively and as 42 degrees postoperatively. Conclusion: After phacoemulsification and intracapsular lens implantation, ultrasonic biomicroscopy showed that the iris diaphragm had shifted backwards, widening the angle of the anterior chamber and decreasing intraocular pressure. tr
dc.language.iso en tr
dc.publisher Dove Medıcal Press Ltd tr
dc.subject Anterior chamber depth tr
dc.subject Anterior chamber angle tr
dc.subject Ultrasonic biomicroscopy tr
dc.title Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery tr
dc.type Article tr
dc.contributor.authorID 0000-0002-0960-6805 tr
dc.contributor.authorID 0000-0003-4378-2164 tr
dc.contributor.department Adiyaman Univ, Fac Med, Dept Ophthalmol, tr
dc.contributor.department Diyarbakir Training & Res Hosp, Dept Ophthalmo tr
dc.identifier.endpage 1934 tr
dc.identifier.startpage 1931 tr
dc.identifier.volume 6 tr
dc.source.title Clinical Ophthalmology tr


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account