dc.description.abstract A solar chimney system was established in Adiyaman University campus area designing a special layered soil (27 m diameter and 0.5 m deep drop-circular hole, while the aluminum foil, glass wool, sand, gravel, broken glass trotters windscreen and its top surface, asphalt) on the 0.004 m thick glass laying the panels, 17 m height of 0.8 m in diameter chimney and a height adjustable air inlet collector (periphery) from 0.05 to 0.35 m to investigate the effect of environmental temperature, chimney height, the collector diameter, the value of solar radiation etc on the performance or effectiveness of Solar Chimney (SCS). In this study, on July 22 on 13:00, temperature, air velocity and temperature under collector at point C-2 for different heights (0.05 - 0.35 m) for air inlet portion of collector (periphery) and of special prepared ground floor according to weather conditions (solar radiation, ambient temperature, air velocity) is investigated. Moreover, temperature of ambient, under collector, glass surface and ground under collector along the day with two hours interval and ambient air velocity, temperature and air velocity at point C-2 where turbine is assembled is investigated. Measurements made in the collector air inlet height is now long solar chimney performance dropped the most ideal height 0.05 m, the specific configuration of the ground daily solar radiation and ambient temperature proportional to a heat store and heat it to the night collector environment by giving the system performance increase was observed. Solar chimney of the ground under the collector of solar radiation absorption rates to the performance of the system efficiency can be considered as a parameter. It is observed in the measurements that as long as the collector air inlet height increases, solar chimney performance dropped and the most ideal height becomes 0.05 m. Also, the specific configuration of the ground daily solar radiation and ambient temperature proportional store heat and it increases the performance of the system by giving this heat to the collector environment in evening. Solar radiation absorption rate of ground under the collector in solar chimney should be considered as a parameter that affects efficiency performance of the system. tr
dc.language.iso en tr
dc.publisher Turkish Soc Thermal Sciences Technology tr
dc.subject Solar chimney power plant tr
dc.subject Special ground tr
dc.subject Ground temperature tr
dc.subject Performance tr
dc.title An Experimental Investigation Of The Effect Of Periphery Height And Ground Temperature Changes On The Solar Chimney System tr
dc.type Article tr
dc.contributor.authorID 0000-0002-8406-9966 tr
dc.contributor.department Adiyaman Univ, Vocat High Sch, tr
dc.identifier.endpage 58 tr
dc.identifier.issue 1 tr
dc.identifier.startpage 51 tr
dc.identifier.volume 32 tr
dc.source.title Isı Bılımı Ve Teknıgı Dergısı-Journal Of Thermal Scıence And Technology tr


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster